PK-AZ is a global overcompensation system that assists the operator in reducing power during emergency situations. It activates within PK mode when LAZ is not enabled.

Once active, PK-AZ inserts its rods under two conditions:

  • when the active AR's measured power deviates from its setpoint by more than 2%,
  • or when any AZM probe crosses its emergency threshold.